| Parameter | Value | |-----------|-------| | Product Model | XH-M608 / HCW-M631 | | Input Voltage | DC 6-40V | | Display Accuracy | 0.1V | | Control Accuracy | 0.1V | | Voltage Error | ±0.1V | | Relay Contact Rating | 10A 250VAC / 10A 30VDC | | Relay Model | SRD-05VDC-SL-C | | Relay Output Type | SPDT (NC-COM-NO) | | Operating Current | ≤ 100mA | | Timer Range | 0.01 to 9.59 (HH.MM) | | Dimensions (L x W x H) | 65-66 x 46-47 x 16-19.5mm | | Weight | 33-80g (varies by source) | | Mounting Hole | ~3.3mm diameter |

This comprehensive guide serves as your complete operational manual, covering technical specifications, wiring configurations, and step-by-step programming instructions. Technical Specifications

Factory calibration adjustment. Use with a precise multimeter to correct display voltage误差. Only adjust if you notice significant deviation in the displayed voltage compared to the actual battery voltage. Xh-m608 Manual

: Connect the XH-M608 between the 12V battery and the 12V load. Set P1 to 10.8V and P2 to 14.4V. The relay stays ON as long as voltage is within the safe range. If the battery drops to 10.8V, the relay disconnects the load, preventing deep discharge.

Always test the controller with a low-power load first, use an external fuse, and refer to online tutorials to fill the gaps left by the original manual. | Parameter | Value | |-----------|-------| | Product

Pass the running to your load through the module’s relay contacts. The board breaks the connection when the battery drops below your safety limit. Programming & Menu Parameters

The is a versatile digital battery charge and discharge control module designed to safeguard DC 6–40V battery systems. It features an integrated voltmeter and a programmable relay to prevent overcharging or over-discharging by automatically connecting or disconnecting power based on set voltage thresholds. 1. Key Specifications Only adjust if you notice significant deviation in

Use this architecture when you want to terminate an incoming charging current (such as from an AC-to-DC wall charger, solar charge controller, or wind turbine) once the battery hits its maximum capacity ceiling.

In P2 mode, use and DEC (-) to set the cut-off value. Save and Exit Hold SET for 3 seconds or wait until flashing stops. 5. Practical Examples

A: The XH-M608 can only perform one function at a time (selected via P0). However, its relay can be wired to control either a charger or a load, and the thresholds can be set to protect against both over-voltage and under-voltage conditions in Protection mode (P).

Suitable for batteries within the 6-40V range. Output Type: Relay switch (isolated from control circuit). Dimensions: Approximately Menu Functions ( )